This is a protocol to send commands to the logger when it is connected via cell.
Warning
Do not execute any commands unless you are confident of their function and use! Failure to do so could result in loss of data
| Version | Command | Returns | Description |
|---|---|---|---|
>v2.9.5 |
102 |
1 |
Has device return a level 2 diagnostic packet |
>v2.9.5 |
103 |
1 |
Has device return a level 3 diagnostic packet |
>v2.9.5 |
104 |
1 |
Has device return a level 4 diagnostic packet |
>v2.9.5 |
111 |
1 |
Has device return a data packet |
>v2.9.5 |
120 |
1 |
Has device return an error packet |
>v2.9.5 |
130 |
1 |
Has device return a metadata packet |
>v2.9.5 |
300 |
1 |
Release WDT - this causes the device to power cycle next time the timer comes around |
>v2.9.5 |
401 |
1 |
Dump contents of FRAM |
>v2.9.5 |
410 |
1 |
Erase contents of FRAM |
| N/A | Other | -1 |
Any unsupported command |