[network::brocade::snmp::plugin] mode "hardware" and Brocade 5480 Embedded Blade Switch (HP AJ821B) #5878

@Aleksey-Maksimov

Description

@Aleksey-Maksimov

Hello

We're trying to use a "network::brocade::snmp::plugin" to monitor Brocade 5480 Embedded Blade Switches (a.k.a. HP B-series 8/24c SAN Switch BladeSystem c-Class AJ821B).
The problem is that in "hardware" mode the plugin does not show information about the switch's temperature sensors.

~# ./centreon_plugins.pl' '--plugin=network::brocade::snmp::plugin' '--mode=hardware' 
'--filter-perfdata-adv' '--hostname' 'SW42' '--snmp-community' 'x' 
'--snmp-version' '2c' '--use-new-perfdata' --verbose

OK: All 0 components are ok [].
Checking switch
Checking sensors

At the same time, the switch itself displays this data:

SW42:admin> sensorShow

sensor  1: (Temperature) is Ok, value is 26 C
sensor  2: (Temperature) is Ok, value is 33 C

SW42:admin> tempShow
Sensor  State        Centigrade      Fahrenheit
  ID
====================================================
  1     Ok               26                78
  2     Ok               33                91