Skip to content

dose rate task 9 result conversion may be incorrect #220

@py1sl

Description

@py1sl

task 9 dose rate on a surface states
"The cell tally has units of pSv cm² per source particle (p is pico). Therefore, the tally result must be divided by the surface area of the sphere to make the units into pSv, and then multiplied by the activity (in Bq) of the source to get pSv per second."

I believe it should not be activity but gammas emitted per second, so in the case of Co60 where there are approximately two gamma rays emitted per decay it should be twice the activity.